Chengdu Xionggu Jiashi Electrical Co., Ltd.
|
Price: | 490000.0 RMB |
Payment Terms: | T/T,L/C |
Place of Origin: | Sichuan, China (Mainland) |
Add to My Favorites | |
HiSupplier Escrow |
Function: It can be used for root pass, hot pass, fill & capping welding of pipeline, vertical and horizontal welding of tanks. GMAW and FCAW-GS welding processes can be applied. All position welding of various workpieces can be realized if various tracks are applied.
Configuration: Welding head, LCD portable panel, control cables, digital welding power source (built-in controller)
Features:
Chinese/English display.
The height of the welding head is lower, which is more suitable for the welding in narrow space such as prefabrication of pipeline in refinery plant and urban pipeline construction.
Operated via LCD portable panel, convenient and intuitive, reduce the welder's labor intensity.
Built-in welding expert database, corresponding welding parameters can be modified and called according to the access level.
Smooth transition of welding parameters in each layer and accurate all position welding can be realized.
4G mobile web, WiFi and QR code scanning interfaces are reserved; it can provide remote technical services and data cloud transmission to facilitate real-time quality management.
With welding seam arc tracking function.
1G, 2G, 3G, 4G, 5G, 5GX, 6G and 6GX welding can be realized by applying different tracks.
Main Technical Parameters
Model | A-305 |
Applicable Pipe Diameter | ≥Φ168 mm |
Travel Speed | 0.1~1.5 m/min |
Wire Feeding Speed | 2.5~16 m/min |
Number of Section per Group | 1~180 Sections |
Torch Oscillation Width | 0~50 mm |
Torch Oscillation Mode | Linear/pendular |
Torch Vertical Movement | 0~ 50mm |
Torch Horizontal Movement | 0~50mm |
Torch Inclination Angle | ±45° |
Weight of Wire Spool | 5kg |
Ambient Temperature | -40~55℃ |
Altitude | 4500m |
Ingress Protection | IP54 |
Weight | 15.8kg |
Dimensions (L×W×H) | 600mm×350mm×250mm |
Note:As technology continues to advance, appearance, color and parameters may change. Parameters are for reference only and are not used as inspection criteria for acceptance.